The CPHOS Baspa Series 23L B Class Autoclave is engineered for busy clinical setups needing efficient, high-capacity sterilization. Fully compliant with European Class B standards, this model ensures 100% sterilization of wrapped, hollow, porous, and solid instruments with its advanced multi-stage vacuum cycle and inbuilt steam generation system.

Features:

    • Larger chamber for higher load capacity
    • Same advanced features as 16L model
    • Ideal for busy clinics and hospitals with higher instrument volumes
    • Inbuilt printer and user-friendly display

Technical Specifications:

Parameter

23 Litres

Product Dimensions (W×H×D)

500mm × 440mm × 780mm

Chamber Diameter

250mm

Chamber Length

480mm

Base Bush (W×H)

330mm × 490mm

Max Load (Vacuum)

6.0 kg

Max Load (Non-Vacuum)

2.5 kg

Water Tank Capacity

5 Litres

Instrument Rack Size (L×W×H)

11.5″ × 7.0″ × 6.5″

Operating Temperature

121°C – 134°C

Operating Pressure

0.2 – 2.45 Bar

Voltage

230V / 50Hz

Noise Level @ 1m

< 60 dB

Chamber & Lid Material

SS 316

Tray Material

Aluminium 6061

Class B Sterilization Cycle (with Pressure & Vacuum Phases)

The Class B Autoclave follows a three-phase sterilization cycle that ensures complete penetration of steam, even inside hollow and wrapped instruments.

1. Pre-Vacuum Phase (0 to -0.9 bar)

Multiple vacuum pulses are created to remove air from the chamber. This drops the pressure to approximately -0.9 bar, allowing saturated steam to fully reach internal surfaces of instruments.

2. Sterilization Phase (+2.1 to +2.45 bar)

Steam is introduced and maintained at a constant pressure between 2.1 and 2.45 bar, depending on the selected cycle (121°C or 134°C). This kills all microorganisms, including spores.

3. Post-Vacuum & Drying Phase (-0.8 to -0.9 bar)

A final vacuum removes moisture from the load. Pressure drops again to around -0.9 bar, ensuring dry, sterile instruments ready for immediate storage or use.

Pressure Summary:

Phase

Approx. Pressure

Pre-Vacuum

-0.8 to -0.9 bar

Sterilization

+2.1 to +2.45 bar

Drying (Post-Vac)

-0.8 to -0.9 bar

Pre-Programmed Sterilization Modes (Both Models)

Mode

Sterilization Time

Dry Time

Total Time

121 Fast

18 min

3 min

28 min

121 Wrapped Solids

18 min

5 min

30 min

134 Fast

5 min

3 min

20 min

134 Wrapped Solids

5 min

5 min

23 min

134 Hollow Open

5 min

5 min

23 min

PRION (134°C)

20 min

5 min

40 min

Helix/Bowie-Dick Test

3.5 min

4 min

28 min

Vacuum Test

15 min

What’s Different in 16 & 23 litres?

Only the physical dimensions, chamber size, and load capacity vary between the two:

Model

Chamber Volume

Max Load

16 Litre

16 Litres

4.5 kg (vacuum mode)

23 Litre

23 Litres

6.0 kg (vacuum mode)

Product Catalogue 