The CPHOS Baspa Series 23L B Class Autoclave is engineered for busy clinical setups needing efficient, high-capacity sterilization. Fully compliant with European Class B standards, this model ensures 100% sterilization of wrapped, hollow, porous, and solid instruments with its advanced multi-stage vacuum cycle and inbuilt steam generation system.

Features:
-
- Larger chamber for higher load capacity
- Same advanced features as 16L model
- Ideal for busy clinics and hospitals with higher instrument volumes
- Inbuilt printer and user-friendly display
Technical Specifications:
Parameter |
23 Litres |
|
Product Dimensions (W×H×D) |
500mm × 440mm × 780mm |
|
Chamber Diameter |
250mm |
|
Chamber Length |
480mm |
|
Base Bush (W×H) |
330mm × 490mm |
|
Max Load (Vacuum) |
6.0 kg |
|
Max Load (Non-Vacuum) |
2.5 kg |
|
Water Tank Capacity |
5 Litres |
|
Instrument Rack Size (L×W×H) |
11.5″ × 7.0″ × 6.5″ |
|
Operating Temperature |
121°C – 134°C |
|
Operating Pressure |
0.2 – 2.45 Bar |
|
Voltage |
230V / 50Hz |
|
Noise Level @ 1m |
< 60 dB |
|
Chamber & Lid Material |
SS 316 |
|
Tray Material |
Aluminium 6061 |
Class B Sterilization Cycle (with Pressure & Vacuum Phases)
The Class B Autoclave follows a three-phase sterilization cycle that ensures complete penetration of steam, even inside hollow and wrapped instruments.
1. Pre-Vacuum Phase (0 to -0.9 bar)
Multiple vacuum pulses are created to remove air from the chamber. This drops the pressure to approximately -0.9 bar, allowing saturated steam to fully reach internal surfaces of instruments.
2. Sterilization Phase (+2.1 to +2.45 bar)
Steam is introduced and maintained at a constant pressure between 2.1 and 2.45 bar, depending on the selected cycle (121°C or 134°C). This kills all microorganisms, including spores.
3. Post-Vacuum & Drying Phase (-0.8 to -0.9 bar)
A final vacuum removes moisture from the load. Pressure drops again to around -0.9 bar, ensuring dry, sterile instruments ready for immediate storage or use.
Pressure Summary:
Phase |
Approx. Pressure |
|
Pre-Vacuum |
-0.8 to -0.9 bar |
|
Sterilization |
+2.1 to +2.45 bar |
|
Drying (Post-Vac) |
-0.8 to -0.9 bar |
Pre-Programmed Sterilization Modes (Both Models)
Mode |
Sterilization Time |
Dry Time |
Total Time |
|
121 Fast |
18 min |
3 min |
28 min |
|
121 Wrapped Solids |
18 min |
5 min |
30 min |
|
134 Fast |
5 min |
3 min |
20 min |
|
134 Wrapped Solids |
5 min |
5 min |
23 min |
|
134 Hollow Open |
5 min |
5 min |
23 min |
|
PRION (134°C) |
20 min |
5 min |
40 min |
|
Helix/Bowie-Dick Test |
3.5 min |
4 min |
28 min |
|
Vacuum Test |
– |
– |
15 min |
What’s Different in 16 & 23 litres?
Only the physical dimensions, chamber size, and load capacity vary between the two:
Model |
Chamber Volume |
Max Load |
|
16 Litre |
16 Litres |
4.5 kg (vacuum mode) |
|
23 Litre |
23 Litres |
6.0 kg (vacuum mode) |